Treatment of Deep Sealed Fire Zone in Foundation Soil of an Oil Tank Area in Fushun
DOI:
CSTR:
Author:
Affiliation:

Liaoning Institute of Engineering Investigation,Dongyan Geology Mapping and Surveying Co., Ltd.

Clc Number:

TU472

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The lower part of a key project of oil tank area is backfilled by overburden from open pit mining for more than 30 years with different level of gas discharging, heat generating and self-ignition. Treatment should be done to the deep sealed fire zone of the oil tank area to ensure the safety of the upper proposed oil tank. Analysis is made on the advantages and disadvantages of grouting methods; by the comparison of different schemes, compaction grouting with water, fly ash and paralysant was adopted with good effect. The paper introduces the grouting design, construction process and the grouting effect.

    Reference
    Related
    Cited by
Get Citation
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:November 12,2012
  • Revised:November 12,2012
  • Adopted:February 19,2013
  • Online: March 25,2013
  • Published:
Article QR Code