This paper introduces the machinery and equipment for geothermal well construction, and describes the stratification drilling measures: 3-section and 2-cementing for well completion, drilling tool matching, mud property, well cementing and pumping test. It was unfavorable for further development and utilization with wellhead water temperature of 63.5 ℃ and flowing yield only 421.9 m3/d. Another directional well was planed to construct 700 m away from the original well; and the design scheme was put forward.
参考文献
相似文献
引证文献
引用本文
任良治,田正权,邝光升,等.静观ZK1号地热井的施工及开发利用计划[J].钻探工程,2010,37(10):48-50.REN Liang-zhi, TIAN Zheng-quan, KUANG Guang-sheng, et al. Construction of Jingguan ZK1 Geothermal Well and Development & Utilization Plan[J]. Drilling Engineering, 2010,37(10):48-50.