The geological conditions under Yichun City Audit Bureau Compartment Building are very complicated. Determination of proper load bearing layer of formation is key to foundation design. After evaluation and analyses on the formation conditions and existing local experiences as well as new pile foundation technology, the load bearing layer of piles were courageously put on the detritus soil layer which is unconsolidated, character various greatly and bearing capacity low. Bottom enlargement of bored piles was adopted to enhance the bearing capacity. Post grouting was used to reinforce the bottom of piles. The practice verified that the alternative was technically feasible and economical.
参考文献
相似文献
引证文献
引用本文
罗绍明,罗增裕.宜春市审计局综合楼钻孔扩底灌注桩加后压浆设计分析及应用效果[J].钻探工程,2005,32(2):9-11.LUO Shao-ming, LUO Zeng-yu. Analyses on and Results of Post Grouting Design for Bottom Enlargement of Bored Piles[J]. Drilling Engineering, 2005,32(2):9-11.